The mouse did not survive interrogation.

Also mouse not pictured.

  • tenchiken@anarchist.nexus
    cake
    link
    fedilink
    English
    arrow-up
    3
    ·
    2 hours ago

    Mine would be when I had a 48 bay disk array / JBOD fail on me… badly. After a storm, it killed the larger card that allowed for me to get many of the drives into a PCIe 16x slot, and I was relegated down to only getting ~8 disks per box made from spare hardware. A single box I got 16 going. Add to this mix an SSD for mid-line caching.

    These were all running bcache on top of mdraid… One single mount.

    Yes I understand how obnoxiously stupid it was to run RAID6 on a 48 disk volume. It was almost all just stuff I could re-acquire over time, not irreplaceable things.

    I just HAD to solve this one though.

    In come several spare chassis / mobo etc… get a bunch of drives powered and on /dev/ , move to the next.

    A couple spare gigabit switches…

    several gigabit NICs…

    two explicit paths for each machine…

    a bit of iSCSI magic, and one machine now had the physical disks all exposed to it… mdadm --assemble blah blah, bit of UUID chaos…

    It’s surprising that while a bit speed limited (I think I got just around 110MB/sec reads), it was nicely performant for what a huge mess of wires and disks just strewn out around my rack.

    Managed to evacuate all I needed without much issue once I got that going. Now, I try to keep my arrays under 16 drives at a time, or keep a very rigid policy of “I can lose this and don’t care” vs “this box gets RAID10 and/or offsite backups nightly”.

    back up your critical stuff people!

    • Shimitar@downonthestreet.eu
      link
      fedilink
      English
      arrow-up
      3
      ·
      2 hours ago

      48 disks seems a nightmare in power consumption, failure rate, and overall cabling management…

      What was the total capacity?

      • tenchiken@anarchist.nexus
        cake
        link
        fedilink
        English
        arrow-up
        2
        ·
        20 minutes ago

        Power isn’t so bad really. These were all 2tb disks, so ended up with about 40tb total after shenanigans.

        Cabling was atrocious. I’d originally been using several pulled 4 disk SAS backplanes from servers thrown out of my work, just screwed down to some pine boards in a stack.

        Zip ties and sata/sas cables were the rule.

        Overall the drives had 4 small power supplies initially, 300watt iirc. Cheap.

        Somewhere I have an old photo from the wiring during the “rescue” but I have to look around.

        Disk failure was actually not an issue for ages before. A specific thunderstorm with 2 nearby tornadoes is what caught me this time. Before that, the occasional single disk every 6 months or so.

        I still have running arrays using 15 year old disks, many with more than 10 years of that powered on. If you find good models, they can last ages.